Office : +603 – 2742 7468
Email : info@muser-my.com
Mon – Fri : 8:30AM – 5:30PM
Food Safety, Laboratory, Test & Measuring Instruments
HIKVISION Thermal Detection & Face Recognition Terminal | Muser Apac

HIKVISION Face Recognition Terminal

  • Temperature measuring range: 30 °C to 45 °C (86 °F to 113 °F)
  • Recognition distance: 0.3 to 1.8 m
  • Face mask wearing alert: If the recognizing face does not wear a mask, the device will prompt a voice reminder.
Share on facebook
Share on twitter
Share on linkedin

HIKVISION Thermal Detection & Face Recognition Terminal

DS-K1TA70MI-T

 

  • Supports Vanadium Oxide uncooled sensor to measure target’s temperature
  • Temperature measuring range: 30 °C to 45 °C (86 °F to 113 °F), accuracy: 0.1 ° C, deviation: ± 0.5 °C
  • Recognition distance: 0.3 to 1.8 m
  • Fast temperature measurement mode: Detects face and takes temperature without identity authentication
  • Multiple authentication modes are available: card and temperature, face and temperature, card and face and temperature, etc
  • Face mask wearing alert: If the recognizing face does not wear a mask, the device will prompt a voice reminder. At the same time, the authentication or attendance is valid
  • Forced mask wearing alert: If the recognizing face does not wear a mask, the device will prompt a voice reminder. At the same time, the authentication or attendance will be failed
  • Displays temperature measurement results on the authentication page
  • Triggers voice prompt when detecting abnormal temperature
  • Configurable door status (open/close) when detecting abnormal temperature
  • Transmits online and offline temperature information to the client software via TCP/IP communication and saves the data on the client software
  • Face recognition duration < 0.2 s/User; face recognition accuracy rate ≥ 99%
  • 6000 face capacity, 6000 card capacity, and 100,000 event capacity
  • Suggested height for face recognition: between 1.4 m and 1.9 m
  • Supports 6 attendance status, including check in, check out, break in, break out, overtime in, overtime out
  • Watchdog design and tamper function
  • Audio prompt for authentication result
  • NTP, manually time synchronization, and auto synchronization
  • Connects to external access controller or Wiegand card reader via Wiegand protocol
  • Connects to secure door control unit via RS-485 protocol to avoid the door opening when the terminal is destroyed
  • Imports and export data to the device from the client software

* Biometric recognition products are not 100% applicable to anti-spoofing environments. If you require a higher security level, use multiple authentication modes.
* In order to get an accurate temperature, after the device is powered on, you should wait for 90 min to warm the device up.

OPTIONAL ACCESSORIES 1

HIKVISION DS-KAB671-B
Mounting Pole

OPTIONAL ACCESSORIES 2

HIKVISION DS-DM0701BL
Desktop Support

OPTIONAL ACCESSORIES 3

HIKVISION DS-KC001
Video Intercom Monitoring Tablet

  • 7-inch colorful touch screen with resolution 1024 × 600
  • Remote temperature screening & records checking, real time preview
  • Centralized data management, max to 100,000 records
  • Abnormal temperature alarm
  • Remote access control & video intercom

Demo Video

HIKVISION DS-K1TA70MI-T Face Recognition Terminal
Temperature measurement
Temperature range 30 °C to 45 °C (86 °F to 113 °F)
Sensor Vanadium Oxide uncooled sensor
Resolution 120 × 160
Frame rate 25 fps
Measurement accuracy 0.1 °C
Measurement deviation ± 0.5 °C, without black body calibration
Measuring distance 0.3 to 1.8 m
Screen
Size 7-inch
Type Touch screen
Camera
Pixel 2 MP
Lens Dual-lens
Network
Wired network Support, 10/100/1000 Mbps self-adaptive
Interface
Network interface 1
Lock output 1
Exit button 1
Door contact input 1
Authentication
Card type Mifare 1 card
Function
Face anti-spoofing Support
Audio prompt Support
Others
Working temperature 0 °C to 50 °C (32 °F to 122 °F) For temperature measurement: 10 °C to 35 °C (50 °F to 95 °F)
Working humidity 10 to 90% (No condensing)
Application environment Indoor and windless environment use only
HIKVISION DS-KC001 Video Intercom Monitoring Tablet System Parameters
Memory 1 GB
Flash 4 GB
Operation System Android 5.1
Network parameters
Network protocol TCP/IP, Private SIP, RTSP
Wired network interface 10/100 Mbps self-adaptive
Wireless network interface Wi-Fi 802.11 b/g/n
Audio parameters
Audio input Built-in omnidirectional microphone
Audio output Built-in loudspeaker
Volume Adjustable
Audio compression standard G.711 U, G.711 A
Audio compression rate 64 Kbps
Audio quality Noise suppression and echo cancellation
General
Power supply 12 VDC
Power consumption ≤ 5 W
Working temperature -10 °C to 50 °C (14 °F to 122 °F)
Working humidity 10% to 90%
Dimensions 200 mm × 140 mm × 15.5 mm (7.87'' × 5.51'' × 0.61'')
Display Parameters
Display Screen 7-inch colorful TFT touch screen
Display Resolution 1024 × 600
Operation Method Capacitive touch screen
Device interfaces
TF card Built-in 32 G TF card
Alarm Parameters
Alarm Input 8
Device Interfaces
Network Interface RJ45
RS-485 1
Debug 1
 
 
Scroll to Top
×