Office : +603 – 2742 7468
Email : info@muser-my.com
Mon – Fri : 8:30AM – 5:30PM
Food Safety Expert | Laboratory Equipment | Test & Measuring Instruments
testo Malaysia 445 | Climate Measuring Instrument (6 Parameters)

testo 445 | Climate Measuring Instrument | Temperature, Humidity, Velocity, Ambient CO, Ambient CO2, Pressure

  • Multi-function climate measuring instrument: measure up to 6 measurement parameters at the same time
  • Internal reading memory for up to 3,000 readings
  • Automatic allocation of the duct cross-section to the measuring location (max. 99 measuring locations)
  • Automatic mean value calculation and determination of the volume flow
SKU: 0560 4450 Category:

testo Malaysia 445 | Climate Measuring Instrument (6 Parameters)

  • Multi-function climate measuring instrument: measure up to 6 measurement parameters at the same time
  • Internal reading memory for up to 3,000 readings
  • Automatic allocation of the duct cross-section to the measuring location (max. 99 measuring locations)
  • Automatic mean value calculation and determination of the volume flow

You can keep a close eye on indoor air quality with the testo 445 climate measuring instrument: the allrounder can measure up to 6 parameters (with the appropriate probe), which can help you make a professional assessment of indoor air quality. The climate measuring instrument therefore supports you in adjusting and checking ventilation and air conditioning systems.
This meter uses a sensor to start up.
 
Product Description
Ventilation and air conditioning systems are used more and more frequently to ensure user independent fresh air supply and thermal comfort in buildings. The testo 445 climate measuring instrument helps you check the system is functioning properly and operating efficiently. This is because the measuring instrument can determine all the relevant measurement parameters for you.
 
testo 445 climate measuring instrument: an overview of the advantages
The testo 445 climate measuring instrument has two inputs for connecting external probes (which can be ordered separately). At Testo, you have a large selection of suitable probes for the testo 445 climate measuring instrument. Depending on which probe you decide on, you can determine the following parameters:

  • Air velocity (in ventilation ducts, at duct outlets and on extractors)
  • Volume flow
  • Indoor air quality (CO2)
  • Temperature
  • Relative air humidity
  • Dew point
  • Absolute humidity
  • Degree of humidity
  • Enthalpy
  • Pressure
  • CO in indoor air

Further practical features of the climate measuring instrument: its internal memory records up to 3,000 readings. The automatic allocation of the duct cross-section is also particularly useful. This means you can save the measurement data so that it is linked to the measuring location (up to 99 measuring locations). The mean value, the last measured value and the min./max. values can be displayed simply by pressing a key.
As optional accessories for the climate measuring instrument, we recommend you get the testo fast printer to print data out directly at the measuring location and the ComSoft software for convenient data analysis on the PC.
 
Delivery Scope
testo 445 climate measuring instrument, including battery and calibration protocol.
 
View our range of testo products here!
Or visit testo website

Temperature - NTC
Measuring range-50 to +150 °C
Accuracy±0.5 % of mv (+100 to +150 °C) ±0.2 °C (-25 to +74.9 °C) ±0.4 °C (-50 to -25.1 °C) ±0.4 °C (+75 to +99.9 °C)
Resolution0.1 °C (-50 to +150 °C)
 
Temperature - TC Type K (NiCr-Ni)
Measuring range-200 to +1370 °C
Accuracy±0.3 °C (-60 to +60 °C) ±(0.2 °C + 0.5 % of mv) (Remaining Range)
Resolution0.1 °C (-200 to +1370 °C)
 
Temperature - TC Type J (Fe-CuNi)
Measuring range-200 to +1000 °C
Accuracy±0.5 °C or ±0.5 % of mv
Resolution0.1 °C (-200 to +1000 °C)
 
Humidity - Capacitive
Measuring range0 to 100 %RH
AccuracySee probe data
Resolution0.1 %RH (0 t1 +100 %RH)
 
Velocity - Vane anemometer
Measuring range0 to 60 m/s
AccuracySee probe data
Resolution0.01 m/s
 
Ambient CO
Measuring range0 to 10000 ppm 0 to 1 Vol.%
Accuracy±(100 ppm + 3 % of mv) (5000 to 10000 ppm) ±(500 ppm + 2 % of mv) (1 to 5000 ppm) Vol %: see probe data
Resolution1 ppm 0.0001 Vol.%
 
Velocity - Thermal anemometer
Measuring range1 to +20 m/s
AccuracySee probe data
Resolution0.01 m/s (1 to 10 m/s) 0.1 m/s (10.1 to 20 m/s)
 
Ambient CO
Measuring range0 to 500 ppm
Accuracy±5 % of mv (100 to 500 ppm) ±5 ppm (0 to 100 ppm)
Resolution1 ppm (0 to 500 ppm)
 
Pressure measurement
Measuring rangeSee pressure probes
Accuracy±0.001 hPa (Probe 0638 1345) ±0.001 hPa (Probe 0638 1445) ±0.01 hPa (Probe 0638 1545) ±1.0 hPa (Probe 0638 1645)
 
General technical data
Dimensions215 x 68 x 47 mm
Operating temperature0 to +50 °C
HousingABS
Warranty2 years
Battery type9V block battery, 6F22
Battery life45 h
Display typeLCD
Display size4 lines
Data transferRS232
Memory3,000 measuring values
Storage temperature-20 to +70 °C
Weight255 g
 
Product Brochures   Manuals  
Scroll to Top
×