Atago Digital Refractometer RX-9000α -High Accuracy- | Refractive Index (nD) 1.325~1.700, Brix 0~100% | Code 3263

  • Very high accuracy measurements up to RI (nD) ±0.00004 and Brix ±0.03%.
  • Equipped with Automatic Temperature Compensation (ATC) feature.
  • Can be connected to a PC using RS-232 adapter.

Atago Malaysia | 3263 Digital Refractometer RX-9000α -High Accuracy- | Refractive Index (nD) 1.325~1.700, Brix 0~100%

Calibration with waterDigital display
AC outlet (AC100 to 240V)Automatic Temperature Compensation (ATC)
High temperature samplesRS-232C Interface
User scales can be inputtedCan be connected to a printer
Measurement at a set temperatureRefractive index scale

 

  • The RX-9000α is a fully automatic digital refractometer with the highest level of accuracy of its kind.
  • Designed with a wide measurement range, measurement temperature range, and highest measurement accuracy, this instrument is suitable for multiple sample types ; such as measuring oils and fats with high melting points, aroma oils of high refractive index and organic solvents, meeting demands for high accuracy measurements.
  • The RX-9000α has a built-in Peltier thermo module for maintaining a constant sample temperature while taking measurements. Manual calibration is also possible to adjust to standard liquid values and to correct differences in measurement values between instruments.
  • This product comes standard with a two (2) year limited warranty against manufacturer’s defects from the date of the original purchase. The warranty period can be extended to three (3) years if the product is registered with ATAGO.
  • FDA 21 CFR Part 11 Software Included in Standard Delivery.

 
3263 Digital Refractometer RX-9000α -High Accuracy- | Features
World’s Highest Standard of Accuracy
The RX series are the most accurate of ATAGO refractometers programmed with a trusted and advanced algorithm. The epitome of which boasts the accuracy of ±0.000010 nD and ±0.005% Brix.
Main Features

  1. Visual “Pass/Fail” Indication
  2. Programmable User Scale
  3. Password Security

FDA 21 CFR Part 11
Software is available to support your FDA 21 CFR Part 11 compliance.
Ergonomically Designed Layout
The RX- a series was designed with ease of use in mind. Extensive research was performed in the design phase to ensure an ergonomic interface that made operation easy while maximizing efficiency.
4 Measurement Mode Options
MODE-1: For maximum accuracy
Displays the measurement value once the sample reaches the target temperature.
MODE-3: For no temperature control
Provides an option to turn the thermo-module off. Without temperature control, the measurement value is displayed in 4 seconds after the START key is pressed.
MODE-2: For fast results
Measures refractive index and temperature at fixed intervals and displays the estimated measurement value at the target temperature.
MODE-S: For emulsion samples
Displays the measurement value once a certain level of sample stability is achieved.

Please click the image below:

 
Tried, tested, and proven features and design

 
3263 Digital Refractometer RX-9000α -High Accuracy- | Application Examples
Refractive Index
Refractive Index is a common quality standard measure for pharmaceutical or chemical products. Measurements need to be taken at a constant temperature, commonly 20°C, 25°C, and 40°C. The RX-α units are equipped with the internal Peltier Thermo-Module, and measurement starts once the target temperature is reached.

Fragrance and Food AdditivesPharmaceutical ProductsCosmetics
Petroleum and Organic SolutionsOils and FatsDetergents

 
Brix
Brix is measured for quality control purposes in the food and beverage industries. The RX-α units are widely used for fruit juice, condiments, jams, and honey. The RX-007α (minimum indication 0.001% Brix) is used for tea and unsweetened drinks.

Beverages and Fruit JuiceJams, Honey, Liquid Sugar, SyrupsCondiments, Sauces, Soups

 
Concentrations
The concentrations of industrial solutions are often monitored. Examples include water-based cutting oils and cleaning solutions, hydrogen peroxide, coolants, and alcohol solutions. Although the Brix scale is commonly used, user scales can also be programmed to display converted sample values.

Chemical SolutionsCutting Oil and Quenching OilAntifreeze and Coolants

 
3263 Digital Refractometer RX-9000α -High Accuracy- | Measurement Method
4 easy steps:

1. Place a sample on the prism.2. Press the START key to start a measurement.3. Measurement value is displayed.4. Wipe off the sample to clean.

 

Click here to visit our range of Atago products!

Or visit Atago Global Website!

Specifications
ModelRX-9000α
Cat.No.3263
ScaleRefractive index Brix
Measurement RangeRefractive index (nD) : 1.32500 to 1.70000 Brix : 0.00 to 100.00% (ATC : 5 to 70°C)
ResolutionRefractive index (nD) : 0.00001 Brix : 0.01% Temperature: 0.01°C
Measurement Accuracy *RepeatabilityRefractive index (nD) : ±0.00004 *±0.00002 (nD 1.33299 to1.42009 at Measurement Temperature 10.00 to 30.00°C) Refractive index (nD) : ±0.00010 *±0.00005 (For ranges other than the above) Brix±0.03% *±0.01% (Brix 0.00 to 50.00% at Measurement Temperature 10.00 to 30.00°C) Brix±0.05% (Brix 50.01 to 95.00% at Measurement Temperature 10.00 to 30.00°C) Brix±0.10% *±0.02% (For ranges other than the above, with Sucrose solution by MODE-1)
Temperature control range5.00 to 70.00°C (Lowest is ambient temp -10°C)
Measurement Temperature5 to 70°C
Power SupplyAC100V to 240V, 50/60Hz
Dimensions & Weight37×26×14cm, 6.8kg (Main Unit only)
Power consumption65VA
ModeMODE-1: Displays the measurement value once the sample reaches the target temperature.MODE-2: Measures refractive index and temperature at fixed intervals and displays the estimated measurement value at the target temperature.MODE-3: The thermo-module can be turn off. Without temperature control, the measurement value is displayed in 4 seconds after the START key is pressed.MODE-S: Displays the measurement value once a certain level of sample stability is achieved.
Output terminals• Printer (for ATAGO digital printers) • Computer - RS-232C Connection to a USB port requires a USB to RS-232 adapter (optional)
Warranty2 years standard (3 years with product registration)