testo 330-1 LL | Flue Gas Analysis Set with Bluetooth

testo 330-1 LL | Flue Gas Analysis Set with Bluetooth

  • High-resolution colour display for the graphic representation of your measurement data
  • Extended measurement menus – such as gas pipe testing – for a comprehensive analysis of your heating system
  • Logger function for easy long-term recording of the measurement curve
SKU: 0632 3306 70 Category:
  • Description
  • Technical Data
  • Downloads

Description

testo Malaysia 330-1 LL | Flue Gas Analysis Set w/Bluetooth

  • testo 330-1 LL flue gas analyzer with long-life gas sensors
  • BLUETOOTH and with H2-compensated CO-sensor, incl. rech. battery and calibration protocol
  • With graphic display
  • Version 2010

Product Description 

Thanks to the new instrument functions, the Testo flue gas analyzers of the new testo 330-LL series now offer you even more professional and reliable support. These are the main features:

  • High-resolution colour display for the graphic representation of your measurement data
  • Extended measurement menus – such as gas pipe testing – for a comprehensive analysis of your heating system
  • Logger function for easy long-term recording of the measurement curve

 

Applications

Ambient CO measurement in the heated environment
Carbon monoxide (CO) is a colourless, odourless and taste-free gas, but also poisonous. It is produced during the incomplete combustion of substances containing carbon (oil, gas, and solid fuels, etc.). If CO manages to get into the bloodstream through the lungs, it combines with haemoglobin thus preventing oxygen from being transported in the blood; this in turn will result in death through suffocation. This is why it is necessary to regularly check CO emissions at the combustion points of heating systems and the surroundings.

Measuring pressure on burners (nozzle pressure, gas flow pressure, etc.)
Standard readings taken during services of domestic heating systems include checking the gas pressure on the burners. This involves measuring the gas flow pressure and gas resting pressure. The flow pressure, also called supplied pressure, refers to the gas pressure of the flowing gas and resting pressure of the static gas. If the flow pressure for gas boilers is slightly outside the 18 to 25 mbar range, adjustments must not be made and the boiler must not be put into operation. If put into operation nonetheless, the burner will not be able to function properly, and explosions will occur when setting the flame and ultimately malfunctions; the burner will therefore fail and the heating system will shut down.

Measuring the flue gas parameters of the burner (CO, O2, and temperature, etc.)
The flue gas measurement for a heating system helps to establish the pollutants released with the flue gas (e.g. carbon monoxide CO or carbon dioxide CO2) and the heating energy lost with the warm flue gas. In some countries, flue gas measurement is a legal requirement. It primarily has two objectives:

  1. Ensuring the atmosphere is contaminated as little as possible by pollutants; and
  2. energy is used as efficiently as possible.

Stipulated pollutant quantities per flue gas volume and energy losses must never be exceeded.

Measurement in terms of results required by law takes place during standard operation (every performance primarily using the appliance). Using a Lambda probe (single hole or multi-hole probe), the measurement is taken at the centre of flow in the connecting pipe (in the centre of the pipe cross-section, not at the edge) between the boiler and chimney/flue. The measured values are recorded by the flue gas analyzer and can be logged either for print out or transfer to a PC at a later stage.

Measurement is taken by the installer at commissioning, and if necessary four weeks later by the flue gas inspector/chimney sweep, and then at regular intervals by the authorised service engineer.

Measuring temperatures on radiators
When measuring temperatures on radiators, the flow and return temperature are recorded in particular and assessed by the tradesman. The flow temperature is defined as the temperature of the thermal transfer medium (e.g. water) that the system is supplied with. The temperature of the medium flowing out of the system is accordingly called the return temperature. To prevent losses within the heat distribution system and achieve a better level of efficiency spot recording of flow and return temperatures are necessary. Implementation of relevant measures ultimately leads to hydraulic adjustment on the basis of knowledge about the flow and return temperatures. This defines a procedure with which every radiator or heating circuit of a flat radiator within a heating system is supplied at a set flow temperature with the precise amount of heat needed to achieve the ambient temperature required for the individual rooms. Flawed operating conditions will result in considerable excess consumption of electricity and heating energy. The German Energy Saving Regulation (EnEV) therefore requires hydraulic adjustment for systems being set up or overhauled for this very reason.

 

View our range of testo products here!

Or visit testo website

Differential Pressure – Piezoresistive
Measuring range0 to +300 hPa
Accuracy±0.5 hPa (0.0 to 50.0 hPa)
±1 % of mv (50.1 to 100.0 hPa)
±1.5 % of mv (Remaining Range)
Resolution0.1 hPa

 

Flue gas O₂
Measuring range0 to 21 Vol.%
Accuracy±0.2 Vol.%
Resolution0.1 Vol.%
Reaction time t₉₀< 20 s

 

Flue gas CO (with H₂-compensation)
Measuring range0 to 8000 ppm
Accuracy±10 ppm or ±10 % of mv (0 to 200 ppm)
±20 ppm or ±5 % of mv (201 to 2000 ppm)
±10 % of mv (2001 to 8000 ppm)
Resolution1 ppm
Reaction time t₉₀< 60 s

 

Flue gas COlow
Measuring range0 to 500 ppm
Accuracy±2 ppm (0 to 39.9 ppm)
±5 % of mv (40 to 500 ppm)
Resolution0.1 ppm
Reaction time t₉₀< 40 s

 

Flue gas NO
Measuring range0 to 3000 ppm
Accuracy±5 ppm (0 to 100 ppm)
±5 % of mv (101 to 2000 ppm)
±10 % of mv (2001 to 3000 ppm)
Resolution1 ppm
Reaction time t₉₀< 30 s

 

Flue gas Nolow
Measuring range0 to 300 ppm
Accuracy±2 ppm (0 to 39.9 ppm)
±5 % of mv (40 to 300 ppm)
Resolution0.1 ppm
Reaction time t₉₀< 30 s

 

Flue gas Draught
Measuring range-9.99 to +40 hPa
Accuracy±0.02 hPa or ±5 % of mv (-0.50 to +0.60 hPa)
±0.03 hPa (+0.61 to +3.00 hPa)
±1.5 % of mv (+3.01 to +40.00 hPa)
Resolution0.01 hPa

 

Temperature
Measuring range-40 to +1200 °C *
Accuracy±0.5 °C (0 to +100.0 °C)
±0.5 % of mv (Remaining Range)
Resolution0.1 °C (-40 to +999.9 °C)
1 °C (> +1000 °C)

* Measuring range depends on the connected flue gas probe

 

Flue gas degree of effectivity, Eta (calculated)
Measuring range0 to 120 %
Resolution0.1 %

 

Flue gas loss (calculated)
Measuring range0 to 99.9 %
Resolution0.1 %

 

Flue gas CO₂ calculation (calculated from O₂)
Measuring range0 to CO₂ max (Display range)
Accuracy±0.2 Vol.%
Resolution0.1 Vol.%
Reaction time t₉₀< 40 s

 

Pressure measurement
Measuring range0 to +300 hPa
Accuracy±0.5 hPa (0.0 to 50.0 hPa)
±1 % of mv (50.1 to 100.0 hPa)
±1.5 % of mv (Remaining Range)
Resolution0.1 hPa

 

Flue gas CO (without H₂-compensation)
Measuring range0 to 4000 ppm
Accuracy±20 ppm (0 to 400 ppm)
±5 % of mv (401 to 2000 ppm)
±10 % of mv (2001 to 4000 ppm)
Resolution1 ppm
Reaction time t₉₀< 60 s

 

Ambient CO
Measuring range0 to 500 ppm
Accuracy±5 ppm (0 to 100 ppm)
±5 % of mv (> 100 ppm)
Resolution1 ppm
Reaction timeApprox. 35 s

with CO probe 0632 3331

 

Ambient CO₂
Measuring range0 to 1 Vol.%
0 to 10000 ppm
Accuracy±75 ppm or ±3 % of mv (0 to 5000 ppm)
±150 ppm or ±5 % of mv (5001 to 10000 ppm)
Reaction timeApprox. 35 s

with ambient CO₂ probe 0632 1240

 

Gas leak measurement for combustible gases (via gas leak detection probe)
Measuring range0 to 10000 ppm CH₄ / C₃H₈; Display range
AccuracySignal optical display (LED) audible signal via buzzer
Reaction time t₉₀< 2 s

with gas leak detection probe 0632 3330

 

General technical data
Dimensions270 x 90 x 65 mm
Operating temperature-5 to +45 °C
Protection classIP40
Display size240 x 320 pixels
Display functionColour graphic display
Power supplyRechargeable battery pack 3.7 V / 2.6 Ah; Mains unit 6 V / 1.2 A
Maximum readings500,000 readings
Storage temperature-20 to +50 °C
Weight600 g (without rechargeable battery)